Facilities

Assembly & Testing

Non- Destructive Testing (NDT)

We have a dedicated NADCAP approved in-house NDT facility catering to requirements of Aerospace customers.

Fluorescent Penetrant inspection (PT)

Equipment: 600 x 600mm Part size

Method A & Method D – Immersion method

Machine: Aqueous cleaning line, Pentrant stations -2, Pre-pentrant etching ( Aluminium)

Material: QPL listed materials

Competency: NAS 410 qualified Level II & Level III

Magnetic Particle Inspection (PT)

Equipment: FWDC-Single phase

Technique: Wet Continuous

Machine: Solvent cleaning machine

Material: QPL listed materials

Competency: NAS 410 qualified Level II & Level III

Assembly

  • Helicoil assembly
  • Lee Plug assembly
  • Thermal assembly
  • Pin assembly

Testing

  • Leak Test using air upto 200 bar
  • Flow test using air and oil
  • Pressure Test using oil upto 200bar
  • Dynamic Balancing
  • Quantifiable Cleanliness Inspection by Ultrasonic patch test and Millipore test.
  • Alloy type testing using XRF method

Other facilities

  • Cleaning line (CPW 152)
  • Pre-Penetrant etching
  • Mold Abredable
Non- Destructive Testing (NDT) We have a dedicated NADCAP approved in-house NDT facility catering to requirements of Aerospace customers.
Fluorescent Penetrant inspection (PT)

Equipment: 600 x 600mm Part size

Method A & Method D – Immersion method

Machine: Aqueous cleaning line, Pentrant stations -2, Pre-pentrant etching ( Aluminium)

Material: QPL listed materials

Competency: NAS 410 qualified Level II & Level III

Magnetic Particle Inspection (PT)

Equipment: FWDC-Single phase

Technique: Wet Continuous

Machine: Solvent cleaning machine

Material: QPL listed materials

Competency: NAS 410 qualified Level II & Level III

Assembly

  • Helicoil assembly
  • Lee Plug assembly
  • Thermal assembly
  • Pin assembly

Testing

  • Leak Test using air upto 200 bar
  • Flow test using air and oil
  • Pressure Test using oil upto 200bar
  • Dynamic Balancing
  • Quantifiable Cleanliness Inspection by Ultrasonic patch test and Millipore test.
  • Alloy type testing using XRF method